STUDY 01 / TRACE - CAMP

Only What Is Necessary.

Sometimes, the best solution comes from adding structural sophistication. Oftentimes, though, it can come from removing everything the project doesn’t need.


PROJECT

CAMP - Modular Cabin

DISCIPLINE

Structural Engineering

COLLABORATOR

Trace

FOCUS

Systems / Connections



01

The brief

The project objective was a modular timber cabin system that could be adapted to different sites, climates, and owners. It needed to be simple to construct, deliverable as a flat-pack kit, fire-rated, and robust enough to perform in a wide range of snow and seismic conditions. Foundations were intended to be minimal, ideally using helical piers to reduce site disturbance. Locally-sourced timber framing would be exposed, while connections would be durable and largely concealed.

Although none of these requirements were particularly unusual, the challenge was bringing them all into balance. As has been typical in our work on Trace projects, the clarity of the architectural intent here proved invaluable. It extended well beyond the appearance of the building itself, encompassing questions of material sourcing, fabrication, assembly, adaptability, site impact, and long-term stewardship. While those considerations introduced additional constraints, they also provided a very effective framework for evaluating structural alternatives.


02

The conventional answer

A previous design effort approached the project using a variation of conventional light-frame construction, which was an entirely reasonable place to start. When engineers can classify a structure as a light-frame building with wood structural panel shear walls, the building code considers this a highly ductile seismic system, with plenty of capacity to flex and dissipate lateral forces before damaging the global system of components. In more practical terms, this flexibility allows us to significantly reduce seismic design forces.

The challenge for this project with this approach arises from the fact that reducing forces to a lateral system on paper, without consideration for how that choice impacts every node in the design network, can sometimes lead to complexity elsewhere.

In this case, as the design developed, the original approach became increasingly dependent on heavy connection hardware, robust hold-downs, and highly detailed assemblies. The system worked structurally, but the realities of the detailing began to conflict with many of the project's original goals.


03

Reconsidering the problem

Whenever structural detailing becomes increasingly complicated, it’s usually a sign to step back and briefly reconsider the path you’re on. Given the complexity of the original design, for instance, it seemed prudent to ask whether we were solving the right problem at all. Did it make sense to establish a system up front and then adapt it to the project constraints? Or should we pause, look at the project as a whole, and ask what was the simplest way that structure could help to achieve all of its objectives?

The building itself was modest in scale: a single-story, 16-foot by 16-foot structure with a peak height of roughly 15 feet. Because the structure was inherently light, the total lateral forces involved would be relatively modest regardless of how we approached seismic design and suggested that perhaps lateral considerations shouldn’t drive the entire project. That observation opened the door to solutions that would be impractical at larger scales.


04

Trading a penalty for freedom

Asking that question led us toward a true timber frame system.

From a code perspective, this was, in a way, penalizing the structural design. By choosing this less-ductile system, the seismic response modification factor dropped from 6.5 to 1.25. On paper, the lateral design forces increased dramatically. Whereas for most buildings that would be a serious disadvantage, for this project, the roof diaphragm forces increased from approximately 1 kip to 4 kips. A significant relative increase, for sure, but still low enough to be manageable within the architectural constraints.

In return, we gained the ability to reconsider the structure on its own terms rather than through the constraints of a conventional shear wall system. Instead of forcing the architecture to accommodate a conventional structural approach, we could begin developing a structural system that naturally supported the architecture.


05

A simpler load path

One of the principles we frequently return to is that more direct load paths tend to produce better buildings. They are easier to understand, they are easier to build, perform better in the long-term, and they often require fewer materials and fewer components.

Applying that principle here naturally led toward timber A-frames and trusses that create a direct and efficient lateral-force-resisting system. Rather than distributing forces through layers of sheathing, collectors, straps, and hold-downs, the final design resolves them through a relatively small number of clearly identifiable elements.

There is a certain honesty in this design. Very little is obscured. The systems responsible for supporting the building are largely the same systems that define its character and govern its construction.

Engineering infographic comparing lateral force transfer through a sheathed shear wall and timber frame, with arrows showing load paths, tension, compression, and pile connections.

06

Concise Connections

Traditional concealed timber connections often rely on knife plates and large bolt groups. These can be effective, but they also tend to introduce eccentricities, additional hardware, and significant geometric constraints. As connections grow larger, they become increasingly difficult to conceal and increasingly demanding to fabricate and assemble.

Rather than asking how to make those connections stronger, we asked whether the force transfer mechanism itself could be simplified.

For instance, the eave truss geometry was selected so that the diagonal members operate primarily in compression. Doing so substantially reduced tension demands at their connections and allowed many of the bolts and plates that are normally associated with those joints to disappear altogether.

Similarly, instead of relying on large fastener groups to transfer compression forces out of a web member and into a chord, we introduced a simplified steel shoe that allowed forces to transfer directly through bearing surfaces. The connection became smaller, cleaner, and much easier to conceal. Not because the hardware was more sophisticated, but because the force path itself was much simpler and more direct. Just as importantly, this approach allowed the timber members to be sized almost entirely for compression rather than being enlarged to accommodate a more complicated connection capable of resolving significant bi-directional forces.

3D-rendered wooden beam joint with exposed metal bolts and connector plate

Steel assembly concealed within exposed timber frame

3D-rendered metal mounting bracket with three bolts and slotted support arms

Isolated steel connection assembly


07

The outcome

The final system satisfied goals that initially appeared to be in conflict. The structure remains largely exposed, yet architectural flexibility is preserved. The building can be clad in nearly any way without dependence on solid shear walls. Connections are reduced and simplified. Construction remains compatible with a modular kit-of-parts approach. And the overall structural concept became clearer rather than more complicated.

The final system is not necessarily the only solution that could have worked. It is simply the one that best aligned with all the project's goals, constraints, and construction realities.

The project itself was asking a different question.


08

Philosophy of solutions

Engineering is often described as the process of solving problems. In practice though, the greater challenge is often in deciding which problem should be solved in the first place. The original solution to this project was technically valid, but the project itself was asking a different question.

The architect deserves considerable credit for maintaining and enabling a consistent design philosophy throughout the process. Rather than treating structural engineering as a separate discipline to be accommodated after the fact, the project was approached as an integrated design problem from the outset.

By stepping back and reconsidering what the lateral system truly needed to do, we found an approach that better aligned with the architecture, the construction method, the material philosophy, and the long-term goals of the project.

FOUNDRY STRUCTURAL / STUDIES

Structure in service of architecture.