STUDY 02 / AGGREGATE FOUNDATIONS - MATERIAL INVESTIGATION

Beyond Compressive Strength.

What does it take to turn an unconventional aggregate
into a rational, defensible foundation system?


MATERIAL

Foamed Glass Aggregate

INVESTIGATION

Structural behavior + serviceability

COLLABORATOR

Trace

OUTPUT

Engineering design framework


01 / THE PREMISE

A material that changes the question.

Foamed glass aggregate (FGA) is a lightweight granular material manufactured by heating recycled glass until it expands into a porous, cellular structure. The resulting aggregate is insulating, free-draining, and capable of supporting structural loads.

Unlike conventional dense-graded granular fills, FGA consists of relatively large, irregular particles that can create an uneven initial contact surface beneath a concrete footing or grade beam. Its cellular structure also makes it relatively compressible: the material undergoes appreciable deformation as it develops resistance to applied loads.

For our investigation, the fundamental question was whether FGA could serve as a viable structural bearing stratum. And if so, how should we characterize its behavior, establish appropriate design criteria, and engineer a foundation to work with it?

Diagram comparing direct and bedded bearing of a grade beam on aggregate, showing irregular versus more uniform load distribution with pea-gravel bedding.

02 / COMPRESSION + CREEP

Strong enough
isn’t the same as stable enough.

AeroAggregates has developed a substantial body of testing and technical guidance for its G15 foamed glass aggregate. The published compressive properties are substantial, but values reported at 1%, 5%, 10%, or 20% deformation do not establish an acceptable long-term bearing pressure for a building.

Under sustained loading, foamed glass aggregate can continue to deform. The relevant design question is not simply whether the particles resist crushing, but whether settlement remains acceptable over the life of the structure.

We reviewed AeroAggregates' published compression and creep testing, along with independent plate-load research, and corresponded directly with the manufacturer's technical leadership to better understand the material's behavior and the applicability of the available data. Of particular interest were recommendations for limiting sustained stress to control long-term creep, rather than relying on the material's much higher compressive-strength figures.

From this investigation, we adopted a maximum sustained service-level bearing pressure of 2,500 psf, informed by published creep research and low-creep recommendations. This criterion became one of the governing parameters of our proposed design framework, with actual maximum bearing pressures evaluated against the limit rather than relying on average foundation loading.

PUBLISHED COMPRESSIVE PROPERTIES / SPECIFIED DEFORMATION

15-24

ksf

G15 minimum values reported for different precompression and deformation conditions. These are not allowable sustained bearing pressures.

FOUNDRY FRAMEWORK / SUSTAINED SERVICE PRESSURE

2.5

ksf

Adopted maximum calculated sustained pressure, including local nonuniform effects. A serviceability criterion.

Technical infographic comparing short-term compressive strength with long-term deformation, showing strength data, sustained-stress graphs, creep strain, and serviceability limits.

03 / LOAD DISTRIBUTION

Give each component a defined job.

A narrow footing bearing on coarse aggregate introduces a contact problem. Concentrated column loads and overturning reactions introduce another: nonuniform bearing pressure, which can produce uneven settlement if the foundation cannot adequately redistribute the loads.

We addressed these problems separately. Pea-gravel bedding regularizes contact. Reinforced concrete distributes concentrated reactions. Compacted FGA supports the resulting pressure. The grade beam's stiffness helps control how loads are distributed into the aggregate, limiting localized compression and differential settlement.

We did not assume that the bedding widens the loaded area or that point loads conveniently disperse through the aggregate. The maximum calculated FGA pressure—not merely the average—must remain within the adopted sustained limit.

Structural engineering diagram showing a reinforced concrete grade beam distributing a concentrated load across aggregate soil, with calculated bearing pressure arrows and a sustained pressure limit.

04 / STIFFNESS

From test data to a usable model.

Strength and creep criteria alone do not tell us how a grade beam distributes pressure. For that, we need a support-stiffness model.

Published first-loading static plate-load tests on compacted G15 reported a mean modulus of subgrade reaction of approximately 140 pci, using a 12-inch plate without surcharge. However, the results exhibited considerable variability, and the tested conditions did not fully replicate those of the proposed foundation.

We therefore adopted 100 pci as a reduced design stiffness, approximately 29% below the reported mean. The selection reflected the variability of the test results, differences in plate dimensions and confinement, and the need to represent initial loading rather than the substantially stiffer response observed during reloading. We also reviewed the proposed value with AeroAggregates' technical team, who considered it a conservative and reasonable design assumption.

The modulus of subgrade reaction is not a universal material constant. Foundation dimensions, aggregate thickness, loading history, and underlying soil conditions all influence the response. Our framework uses the adopted value to model grade beams on elastic support, providing a rational basis for evaluating load distribution, bearing pressure, and foundation deformation.

Engineering design slide showing testing near 140 pci reduced to a 100 pci design value, with a schematic grade beam supported by springs.

05 / FROM MATERIAL TO SYSTEM

A tested material is not a tested foundation.

The design must also consider immediate FGA deformation, long-term creep, and settlement of the supporting soil. Meeting a sustained pressure limit does not by itself demonstrate acceptable total or differential settlement.

Drainage, buoyancy, geotextile separation, placement, and compaction matter because they affect the conditions under which the material performs. Lateral load transfer introduces additional interfaces whose resistance cannot be inferred from FGA's internal shear strength.

Some questions remain deliberately open pending project-specific loading and envelope analysis. Recognizing an unresolved mechanism is part of establishing a defensible design basis.


06 / THE RESULT

Making exploration usable.

The result was a project-specific design framework written in a familiar code-and-commentary format: proposed provisions paired with explanations of the data, assumptions, and engineering reasoning behind them.

It is not an adopted building code or a blanket approval of foamed glass foundations. It establishes a documented basis for evaluating and designing FGA-supported foundations within the limits of the available evidence

Its conservatism is purposeful—directed at specific uncertainties in long-term deformation, contact, and pressure distribution rather than applied indiscriminately because the material is unfamiliar.

Engineering infographic showing FGA-7.4 sustained bearing pressure limited to 2,500 psf and FGA-7.5 grade-beam analysis using k = 100 pci.

08 / THE LARGER IDEA

When the code doesn’t have an answer.

New materials do not necessarily require new principles of engineering. They require us to decide which familiar assumptions remain valid, which must be modified, and which need more evidence.

Here, the underlying principles were recognizable: equilibrium, stiffness, load distribution, deformation compatibility, and long-term serviceability.

The objective wasn't to prove that foamed glass aggregate could work. It was to establish the conditions under which we could responsibly design with it.

FOUNDRY STRUCTURAL / STUDIES

Unconventional. Not impossible.

Engineering basis / draft framework. Source materials identified in the delivered framework: AeroAggregates TN 108 (March 2026); TN 112 (May 2020); McGuire, Loux & Filshill (Geo-Congress 2024); project-specific correspondence with AeroAggregates (September 2026). The conceptual illustrations are explanatory and are not tested particle-scale models or construction documents. The engineering framework is not an adopted code and requires project-specific evaluation and approval.